MAN eTGX electric truck feeds up to 350 kW into the grid in SPIRIT-E bidirectional charging trial
By Eve
The SPIRIT-E research project, led by the Technical University of Munich with MAN Truck & Bus and Traton R&D, tested bidirectional charging at Spedition Schmid's depot in Regensburg, Germany, from August 2023 to October 2026. An MAN eTGX with 480 kWh of usable energy fed power through a bidirectional DC charging station at up to 350 kW into the depot network (V2S) and the public grid (V2G), and also charged other vehicles from its battery (V2V). The project implemented ISO 15118-20 and used SBRS mobile and stationary chargers, with PowerBot software simulating buying power at low prices and selling at high prices, as reported by Chris Ruoff on 11 November 2026.
Why it matters
The trial coordinated the vehicle, charger, charging operator software, site energy management, electricity trader and grid operator interfaces on ISO 15118-20, which is the integration work that depot bidirectional projects will need to specify. For CPOs and fleet buyers, it points to heavy duty V2S and V2G becoming a hardware and software requirement to plan for in future tenders.
Source
- Original title
- “MAN electric truck feeds 350 kW back to the grid in SPIRIT-E bidirectional charging project”
- Published
- 11 November 2026
- Updated
- 12 November 2026
In this story
- Topic
- Grid & Energy
- Place
- Global
- Tag
- MAN
Related news
Grid-tied solar without a battery typically shuts down during a blackout, a US homeowner discovers
A homeowner on Reddit's r/SolarDIY said their grid-connected solar system has no battery storage, so it does not supply power when the grid fails, because a typical grid-connected inverter shuts down in an outage. One commenter suggested an AC-coupled battery-backup inverter as the most financially realistic option, while another noted that a gateway or transfer switch would be needed. The report comes from The Cool Down and also mentions $0-down solar leases as a way to manage household electricity costs.
Why it matters
Backup capability depends on batteries plus a gateway or transfer switch, not on panels alone, which is a point to note when scoping solar-linked charging sites that must keep operating in an outage. Consumer expectations about resilience from grid-tied solar are often misplaced, and clear specification and messaging can avoid disputes.
Eversource expands smart meter rollout in Massachusetts, recording power use every 15 minutes
Eversource is rolling out smart meters across Massachusetts that record electricity use every 15 minutes rather than once a month, with installations largely finished in western Massachusetts, according to WBZ-TV as relayed by The Cool Down. The upgrade includes high-energy-use alerts and a data-tracking app, and Cambridge Mayor Sumbul Siddiqui's home is among those receiving a meter. The technology has also prompted customer concerns about personal privacy and the cost of opting out.
Why it matters
Interval metering data at 15 minute resolution is the foundation for time-varying tariffs and managed charging programmes, which can shape site economics and load planning for CPOs in Eversource territory. Privacy concerns and opt-out costs may influence how customer data is shared and how readily such programmes are adopted.
Australian homeowner asks if charging a home battery from solar and free grid power at once risks overheating
A homeowner in Australia with solar and an 18 kilowatt hour battery posted on Reddit's r/SigenergyAustralia, via The Cool Down, asking whether importing grid power and solar at the same time is safe. They had scheduled grid charging from 11 a.m. to 2 p.m. to use a three hour free power offer. One commenter replied that the system will not charge more than the batteries can handle, citing the equipment's charging specifications.
Why it matters
Free and time-limited tariff windows are pushing owners to charge batteries from several sources at once, and the questions they raise show gaps in public understanding of built-in charge limits. For CPOs and installers, clear guidance on how storage-backed systems manage power could reduce customer concern and support calls.