A charger labelled up to 300 kW can deliver less than a 150 kW unit when power is shared
By Eve
A French language article argues that the headline figure on a charger is only one of several limits. A "up to 300 kW" unit can give a car under 150 kW if the 300 kW is split across several outputs, while dynamic allocation can raise a driver's power mid session as other cars draw less. It compares three fictional sites with identical cars, using reserved power, a fixed equal split and dynamic allocation, and cites Kempower's technical manual on the separate limits of vehicle, charge point and site.
Why it matters
Specifying and marketing sites by headline kW can mislead drivers and tenders, so procurement teams should ask how power is shared between outputs and what a driver receives when the site is busy. Power sharing architecture affects real session speed, throughput per bay and how a CPO should describe its offer.
Source
- Original title
- [FR] “Vous choisissez toujours la borne électrique la plus puissante pour recharger ? C’est parfois une erreur”
- Published
- 24 November 2026
- Updated
- 25 November 2026
In this story
- Topic
- EV Charging
- Place
- France
Related news
Chargemap confirms user data theft linked to an old technical interface
Chargemap told users on 18 November 2026 that their data had been stolen, according to its communication as reported by Next and Bevolt. The attack reportedly took place on 8 November, was detected on 10 November and the flaw was fixed on 12 November, with an old technical interface said to be the cause. Exposed data includes email address, username and app language, and depending on the account may also include identity, phone number, date of birth, city, profile photo, subscription status and Google, Facebook or Apple login identifiers. Some former users who deleted their accounts may also be affected, and the company says it has notified the CNIL and is starting a complaint procedure.
Why it matters
Charge point operators and procurement teams that rely on Chargemap for driver discovery, roaming or app integrations should review their data sharing arrangements and security due diligence. The reported cause, a legacy interface, and the possible exposure of deleted accounts are reminders to test data retention and decommissioning as part of supplier assessments.
ChargePoint partners with Kässbohrer to bring DC fast chargers to ski resorts
ChargePoint has partnered with Kässbohrer, maker of the PistenBully slope groomer, to target ski resorts in North America and Europe. The partnership, effective immediately, puts Kässbohrer's customers, from ski resort operators to public parking operators, in direct contact with ChargePoint's hardware and software. Resorts and indoor ski facilities can access a charging ecosystem for electric snow groomers and other EVs in their fleets, according to InsideEVs.
Why it matters
Ski resorts and similar sites are a niche channel for heavy-duty and fleet charging, reached through an established equipment maker's customer base rather than through conventional site acquisition. CPOs and installers may see new demand at remote, cold-climate locations where charger selection could be shaped by the Kässbohrer relationship.
PLUG Charging launches in-house maintenance division and hires Cardiff field engineer
PLUG Charging has brought the testing, inspection, fault response and maintenance of its EV charging network fully under its own management through a new in-house division. Field Engineer Connor Ogden, formerly an Approved Electrician at Virtua UK Ltd, has joined in Cardiff to establish the service, focusing on resilience for depot charging active with Welsh authorities and fault response at PLUG's public charging locations. The company said the move gives it direct control over response times and service quality.
Why it matters
For public sector fleet buyers and CPOs, an operator that handles maintenance in-house offers a clearer line of accountability on uptime than one relying on subcontracted service. It is a signal to test operations and maintenance claims, response commitments and local engineering capacity when assessing charging suppliers.